Process Recordings are stored under GDS/audit/workflow dir.
By default the max.# of recordings that can be stored is set to 50.
With LC ES2, there was a bug with recordings not getting cleaned up automatically when the max. # of recording configured are reached and resulting in – OverlappingFileLockException. This was fixed in LC ES2 SP1 and later. So, after installing ES2 SP1, old recordings will be deleted automatically once the max. limit is reached.
The max. # of recordings value can be configured via workbench -
1. open Component View in Workbench.
2. right click on “Components/AuditWorkflowDSC/AuditWorkflowService:1.0”
3. select “Edit Service Configuration…”
4. change value to increase/decrease max limit.
5. restart service.